A. List ALL major components (active devices, integrated circuits, etc.) except for power sources, voltage regulators, resistors, capacitors, or passive elements

All Major Components

Component Name

Part Number

Supply

#

Absolute

Total

Unit

Microcontroller

PIC18F27Q10-I/SO

1.8 - 5.5V 1 250 250

mA

ADC

ADC081C021

2.7 - 5.7V 1 6 6

mA

OP Amp

OPA2310IDR

1.5 - 5.5V

2 150 300

mA

Barometric Pressure Sensor

KP235XTMA2

3.475 - 5.25V 1 20 20

mA

Voltage Regulator

LM2575D2T

3.3V

1 1000 350

mA

Motor driver

IFX9201SGAUMA1TR-ND

0 - 5.5V

1 13 13

mA

DC Motor

2790-NF123G-302-ND

2.7 - 5.5V 1 800 800

mA

ESP32

ESP32WROOM32

0.3 - 3.6V 1 100 100

mA

B. Assign each major component above to ONE power rail below. Try to minimize the number of different power rails in the design.

+5V Power Rail

Component Name

Part Number

Supply

#

Absolute

Total

Unit

Motor driver

IFX9201SGAUMA1TR-ND

0 - 5.5V

1 13 13

mA

DC Motor

2790-NF123G-302-ND

2.7 - 5.5V 1 800 800

mA

0

mA

0

mA

0

mA

Subtotal 813

mA

Safety Margin 20%
Total Current Required on +5V Rail 975.6

mA

c2. Regulator or Source Choice

Voltage Regulator

LM2575D2T

3.3v

1

1000 1000

mA

Total Remaining Current Available on +5V Rail

24.4

mA

+3.3V Power Rail

Component Name

Part Number

Supply

#

Absolute

Total

Unit

Microcontroller

PIC18F27Q10-I/SO

(range)

1 250 250

mA

ADC

ADC081C021

2.7 - 5.7V 1 6 6

mA

OP Amp

OPA2310IDR

1.5 - 5.5V

2 150 300

mA

Barometric Pressure Sensor

LPS22HHTR

4.5 - 5.75V 1 20 20

mA

Subtotal 576

mA

Safety Margin 25%
Total Current Required on +3.3V Rail 720

mA

c4. Regulator or Source Choice

Voltage Regulator

LM2575D2T

3.3V

1 1000 1000

mA

Total Remaining Current Available on 3.3V Rail

280

mA

C. For each power rail above, select a specific voltage regulator using the same process as for major component selection. Confirm that the Total Remaining Current Available

D. Select a specific external power source (wall supply or battery) for your system, and confirm that it can supply all of the regulators for all of the power rails simultaneously.

External Power Source 1

Component Name

Part Number

Supply

Output

Absolute

Total

Unit

Power Source 1 Selection

Plug in wall supply

#LJH -186

110ADC

9V

1000 1000

mA

Power Rails Connected to External

3.3 V Power Rail

LM2575D2T

3.3V

1

1000 1000

mA

Total Remaining Current Available on External Power Source 1

0

mA

External Power Source 2

Component Name

Part Number

Supply

Output

Absolute

Total

Unit

Power Source 2 Selection

Plug in Wall Supply

#LJH -186

110ADC

9V

1000 1000

mA

Power Rails Connected to External Power Source 2

0

mA

Total Remaining Current Available on External Power Source 2

1000

mA

E. Calculate Battery Life (if applicable). For each battery, also check the worst-case lifetime of the battery by indicating the capacity in mAh.

Component Name

Part Number

Supply

Capacity

Required

0
Battery Life

#DIV/0!

hours

Notes

External Supply Voltage should be determined by the dropout voltage for highest-voltage regulator (e.g., +14V for a +12V regulator).

If you have multiple units in your design (e.g., a base unit and remote unit) then you need a separate power budget for each unit